WhoshouldIsee Tracks

Butterfly valves on data centre and process cooling water

Walk into the plant room of a data centre, a food factory or a manufacturing site, and the large pipes carrying cooling water will almost certainly have butterfly valves on them.
There are good reasons for that, and a few things worth checking before you specify one.

#Industrial Applications

Why butterfly valves on cooling water?

  • Compact and light: a butterfly valve is far shorter and lighter than a gate valve of the same size, which matters in a crowded plant room.
  • Quick to operate: a quarter turn takes it from fully open to fully shut.
  • Cost: at larger sizes, it is usually cheaper than the equivalent gate valve.
  • Low torque: the disc is balanced on its stem, so it takes less effort to turn, and smaller actuators if you automate it.

Wafer or lugged?

A wafer butterfly valve is clamped between two pipe flanges by long bolts that pass right through. It’s the lightest and cheapest option.
A lugged butterfly valve has threaded lugs around the body, so each pipe flange bolts to the valve separately. That makes it easier to take out the pipework on one side while the valve stays in place.
Our range covers both: the Fig BF01 wafer and the Fig BF02 lugged butterfly valve. The BF02 is made to BS EN 593:2017, DN50 to DN600, rated up to 16 bar, with flanges to EN 1092 PN10 or PN16. It has a ductile iron body with a blue fusion bonded epoxy coating, a stainless steel disc and an EPDM seat, and is suitable for temperatures from −35°C to 130°C.

Lever, gearbox or actuator?

Smaller valves usually have a lever; larger ones have a gearbox as standard. If the cooling system is controlled by a building management system, an ISO 5211 actuator mount lets the valve be motorised now or later. More in Does a butterfly valve need a lever or a gearbox?

What should I check before specifying?

  • What’s in the water: many cooling systems use glycol or treatment chemicals. Tell us, so we can confirm the seat material suits it.
  • Temperature: cooling water is usually well within range, but check any hot or heat recovery circuits.
  • Space: allow room for the lever to swing or the handwheel to turn.
  • Locking: a locking device stops critical valves being shut by mistake.

Quick tip: if a cooling loop can’t ever be fully shut down, fit isolation valves either side of every pump, chiller and heat exchanger. Then each one can be serviced while the rest keeps running.

Before you enquire, have ready: pipe size, pressure rating, flange standard, what’s in the water, temperature, wafer or lugged, and how you want to operate it.

Related reading: Does a butterfly valve need a lever or a gearbox? · Does the closing direction of a valve matter? · Butterfly or gate valve?

Contact us now to see how we can help you!

Contact us by email at sales@gavalves.co.uk or call us on 01484 711983

Related Posts

Below you can view our related posts.

Guide

Butterfly valves on data centre and process cooling water

Walk into the plant room of a data centre, a food factory or a manufacturing site, and the

Read More

Guide

Does a butterfly valve need a lever or a gearbox?

Mostly, it comes down to size. But it’s worth thinking about how the valve will be used, too.

Read More

Guide

Knife gate valves for slurry, sludge and solids: where standard valves fail

Quarry silt, digestate from an anaerobic digestion plant, food waste, settled sludge: some liquids are thick, gritty or

Read More